Place of Origin:
China
Brand Name:
YUYANG
Certification:
CE , ISO
Model Number:
YYL-008
200~1100℃ High Temperature Tension Fatigue Testing Machine 150mm
Product Description:
The high temperature test furnace adopts cylinder open structure, which is composed of test furnace, temperature controller. For the temperature controller, it adopts the PID fuzzy control, test temperature overshoot small, high control precision, which is the ideal high performance material testing machine for colleges and universities, research institutions, factories and mine material research institutions.
1. The high temperature furnace adopts drum-type, split structure, electrical resistance wire heating, it can realize the precision of temperature control through control heating time percentage.
2. Temperature controller with PID Mode, digital display the setting temperature and measuring temperature. Test temperature overshoot small and Volatility small
3. This high temperature Furnace is equipped with one crank arm bracket, which is connivent to move the furnace into the testing space and move out after finished.
4. Over-temperature alarm device is also equipped, it can be used for promote action.
Main Technical Parameters:
1. Three sections temperature control design
2. Temperature Range: 200~1100℃
3. Temperature Accuracy: according to HB5195-96B standard amassments.
4. Soaking Zone Length: Isothermal section 150mm
5. Inner size:Φ90×300mm can be customized on user’s requirements
6. Temperature Control Mode: Direct-type (Thermocouple tied with specimen) or indirect type (Thermocouple from furnace side entry)
7. Power:3Kw
8. Temperature fluctuation
≤600℃ ±2℃,
600~900℃ ±3℃,
≥900℃ ±4℃;
9. Temperature Gradient:
≤600℃ 2℃,
600~900℃ 3℃,
≥900℃ 4℃;
10. Temperature Measuring Instrument Accuracy: No less than 0.3 Class
Temperature Range: | 200~1100℃ |
Temperature Accuracy: | according to HB5195-96B standard amassments. |
Soaking Zone Length: | Isothermal section 150mm |
Inner size: | Φ90×300mm (can be customized) |
Temperature Measuring Instrument Accuracy: | No less than 0.3 Class |
Muffle furnace: | lab tensile test muffle furnace |
Send your inquiry directly to us