Place of Origin:
CHINA
Brand Name:
YUYANG
Model Number:
YY098
YYF089 Surgical Facial Flame Retardant Test Machine
Description:
The Flammability test procedure evaluates the flammability of medical textiles including face masks, surgical gowns, and drapes. The test method is designed to comply with 16 CFR Part 1610.
Scope of application
It is mainly used to test the burning performance of medical masks after contacting the flame at a certain linear speed.Able to special test equipment. It is suitable for measuring the flame retardant performance of medical masks and all protective masks. Available for medical inspection. Used by inspection departments, safety inspection departments and scientific research units. It is a test item to test the flame retardant performance of protective masks; through propane as a combustion power source, the system is equipped with gold. Belong to the head mold, bring the mask into the metal head mold, the metal head mold is equipped with a rotating speed that can be adjusted, and a certain shift is set. Dynamic speed and height, through 800 ℃ high temperature combustion, observe and detect the flame retardant performance of protective masks.
Scope of application
It is mainly used to test the burning performance of medical masks after contacting the flame at a certain linear speed.Able to special test equipment. It is suitable for measuring the flame retardant performance of medical masks and all protective masks. Available for medical inspection.
Feature:
1. PLC + touch screen control system; make test more convenient operating, visualization;
2. mask fixture for the metal body head mold, can fully simulate the actual use of the state mask.
3.the burner height can be adjustable
4.automatic timing positioning made by the burner
5.burning time, fire-retardant time are automatically recorded, show the figures.
6.with a flame temperature measurement probe, flame temperature display.
7.automatic control system, automatic ignition;
8.the burner with propane (liquefied gas) and other combustible gas interface.
9.automatic timing, automatic storage of test data; easy access to experimental reports
Technical index
1. The linear motion velocity of the tip of the nose of the head mold: (60 ± 5) mm / s;
2. The flame height can be adjusted (adjusted at the factory to 40 ± 4mm);
3. The diameter of the flame temperature measuring probe: 1.5mm;
4. The height of the flame from the top of the burner: (20 ± 2) mm, the temperature is (800 ± 50) ℃;
5. The distance between the top of the burner and the low point of the mask zui: (20 ± 2) mm;
6. Height adjustment range of burner: 30mm;
7. The wall thickness of the metal head mold is 2 ~ 3mm, which is resistant to flame and flame;
8. Head mold material: iron / aluminum (optional);
9. Combustion gas: propane or liquefied gas, purity above 95% (user-supplied)
Working power supply | AC220V, 50Hz, 50W |
Instrument weight | 70KG |
Accuracy | ± 0.01 seconds |
Dimensions | 1000*650*1300mm |
Warranty | 1 Year |