Product Details
Product Name:
Network Cable Tester Nf-816 Rj11 Rj45 Cat5 Cat6 Underground Telephone Wire Locator Network Cable Wire Tracker Tester Finder
Protection Level:
IPX4
Control Mode:
Intelligent Microcomputer Control
Cooling Method:
Air Cooling
Lamp Life Span:
≥1500 Hours
Temperature Range:
RT+20℃~70℃
Lamp Power & Length:
40W/Piece, 1200mm/Piece
Uniformity Of Light Radiation Intensity:
≥90%
Highlight:

environmental chamber

,

custom environmental chambers

,

environmental control chamber

Payment & Shipping Terms
Minimum Order Quantity
1pcs
Price
Negotiable
Packaging Details
Wooden Box
Delivery Time
7-30 Days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
5 Pcs Per Month
Product Description

Network Cable Tester Nf-816 Rj11 Rj45 Cat5 Cat6 Underground Telephone Wire Locator Network Cable Wire Tracker Tester Finder

 

Description:

The UV Aging Test Lamp is a reliable instrument for conducting sunlight resistance tests on non - metallic materials. It is applicable to materials used in the energy, telecommunications, and transportation industries. Constructed with advanced technology, this lamp can simulate sunlight, humidity, and dew conditions. It can lead to issues like bleaching, loss of transparency, and powdering in the tested materials, enabling manufacturers to optimize the performance of their products.

 

Design criteria:

 

(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings

(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)

(3) ISO 4892-1: Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance

(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps

(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics

(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure

 

Control System:

Control System 5** Utilizes a black anodized aluminum plate to link up with the temperature sensor, and a black - board temperature controller is employed to regulate the heating, ensuring a more stable temperature condition. The radiometer probe is fixed stably to prevent frequent installation and removal activities. The radiation quantity is measured by a dedicated UV irradiometer with high - precision display and measurement accuracy. The radiation intensity is capped at 50W/m². Illumination and condensation can be controlled independently or in an alternating, circular cycle. 

 

Standard specimen size 75×290mm/24 pieces
Power 1 phase, 220V/50Hz /±10% 5KW
blackboard temperature range room temperature 30 ℃ ~ + 80 ℃
Irradiation black panel temperature 50℃~70℃
Material: Stainless Steel
Lifetime of lamp 1600Hours
Lamp power & length 40W/Piece, 1200mm/Piece

 

 

Network Cable Tester Nf-816 Rj11 Rj45 Cat5 Cat6 Underground Telephone Wire Locator Network Cable Wire Tracker Tester Finder 0Network Cable Tester Nf-816 Rj11 Rj45 Cat5 Cat6 Underground Telephone Wire Locator Network Cable Wire Tracker Tester Finder 1Network Cable Tester Nf-816 Rj11 Rj45 Cat5 Cat6 Underground Telephone Wire Locator Network Cable Wire Tracker Tester Finder 2

FAQ

1. How to choose the appropriate model of the ultraviolet aging test chamber?

To choose the appropriate model, you need to consider the type, size, and quantity of the test materials, as well as the range of environmental conditions to be simulated. At the same time, pay attention to the performance parameters of the equipment, brand reputation, and after - sales service to meet the actual test requirements.

2. Can the light intensity of the test chamber be adjusted?

The light intensity of most ultraviolet aging test chambers can be adjusted. By adjusting the light intensity, it is possible to simulate the differences in sunlight intensity in different regions and seasons, making the test conditions more in line with the actual application scenarios.

3.Can the test chamber be opened during the operation of the equipment?

It is not recommended to open the test chamber during the operation of the equipment. Since the inside of the chamber is under specific environmental conditions during operation, sudden opening will disrupt the test environment, affect the accuracy of the test results, and may also pose certain safety risks.